The Tridonic EM converterLED PRO 205 NiCd/NiMH 250V is a self-testing emergency LED conversion unit designed for installation inside compatible luminaires.
It provides a constant 4.5 W emergency output and supports LED modules with a combined forward voltage between 48 and 250 V. Emergency duration can be configured for one, two or three hours using the duration-selection link.
The integrated DALI interface enables central monitoring, configuration and retrieval of emergency-lighting information. The unit automatically carries out a five-second function test every week and a full-duration test annually in accordance with its programmed emergency duration.
Three-pole switching technology provides two-pole LED-module changeover together with delayed power switching for the associated normal LED driver. The same LED module can therefore be illuminated through a separate mains LED driver during normal operation and powered by the emergency converter following a mains failure.
The emergency control gear itself is specified by Tridonic for non-maintained operation. Where the same LED module operates under normal mains conditions, that normal illumination is provided by the separate LED driver rather than by the emergency converter.
The 205 version requires a compatible five-cell, 6.0 V Tridonic NiCd or NiMH battery. The required battery capacity and format depend on the selected emergency duration and must be confirmed using Tridonic’s current compatibility table.
TECHNICAL SPECIFICATION
- Manufacturer: Tridonic
- Manufacturer part number: 89800661
- Model: EM converterLED PRO 205 NiCd/NiMH 250V
- Product type: Self-testing emergency LED conversion unit
- Product range: EM converterLED PRO
- Emergency operating mode: Non-maintained control gear
- Testing system: Automatic self-test and DALI
- Rated supply voltage: 220–240 V AC
- Permitted AC voltage range: 198–264 V
- Mains frequency: 50/60 Hz
- Emergency duration: Selectable 1, 2 or 3 hours
- Typical emergency output power: 4.5 W
- Output characteristic: Constant power
- LED forward-voltage range: 48–250 V
- Maximum open-circuit voltage: 290 V
- Maximum U-OUT: 290 V
- Output classification: Non-SELV
- Emergency starting time: Less than 0.5 seconds
- Compatible battery chemistry: NiCd or NiMH
- Required number of battery cells: 5
- Nominal battery voltage: 6.0 V
- Battery discharge current: 820–880 mA
- Initial battery charge time: 20 hours
- Fast recharge time for one-hour operation: 10 hours
- Fast recharge time for two- or three-hour operation: 15 hours
- Battery charging method: Intelligent continuous trickle charging
- Automatic function test: Weekly, 5 seconds
- Automatic duration test: Annually, according to the selected 1-, 2- or 3-hour duration
- Communication interface: DALI
- Status indication: Compatible bi-colour LED; green for normal operation and red for a fault
- Rest-mode capacity: Up to 100 emergency units
- Maximum rest-mode wiring distance: 1,000 m
- Ambient operating temperature: −25°C to +55°C
- Maximum casing temperature: 80°C
- Ingress protection: IP20
- Mains surge capability, L–N: 1 kV
- Mains surge capability, L/N–PE: 2 kV
- Overvoltage protection: 320 V for 48 hours
- Maximum associated LED-driver load: 150 W
- Maximum associated LED-driver output current: 2 A RMS
- Expected operating life: Up to 100,000 hours
- Guarantee: Five years, subject to Tridonic’s current conditions
- Dimensions: 179 × 30 × 21 mm
- Approximate weight: 73 g
- Manufacturer’s carton quantity: 10 pieces
- Manufacturer’s pallet quantity: 1,600 pieces
- Relevant standards include: EN 50172, EN 60598-2-22, EN 62034, EN 61347-1, EN 61347-2-7, EN 61347-2-13, EN 55015, EN 61547 and EN 62384
PACKAGE CONTENTS
- 1 × Tridonic EM converterLED PRO 205 NiCd/NiMH 250V
- 1 × duration-selection link
Battery, bi-colour indicator LED, test switch, wiring, strain-relief enclosure and other accessories should only be considered included where specifically stated by the seller.
INSTALLATION AND COMMISSIONING
Installation must be completed by a suitably qualified person in accordance with the Tridonic wiring diagram and applicable emergency-lighting regulations.
The required duration must be selected before connecting the battery and mains supply:
- Link in position A: Three hours
- No duration link: Two hours
- Link in position B: One hour
The unit is supplied with the link in the three-hour position.
Following installation:
- Connect only an approved five-cell Tridonic NiCd or NiMH battery
- Connect the bi-colour status-indicator LED
- Configure the required emergency duration
- Allow the battery to complete its initial charge
- Perform a functional test
- Complete and record a full-duration test
- Address and commission the DALI interface where it is being used
The battery, LED output, test-switch and indicator connections must be insulated for the applicable non-SELV voltage within the luminaire.
AUTOMATIC TESTING
The PRO version incorporates automatic emergency-lighting testing:
- Function test: Five seconds every week
- Duration test: Once per year for the selected one-, two- or three-hour duration
- Status indication: Green indicates normal operation; red indicates a detected fault
- DALI reporting: Test results and operational information can be communicated to a compatible DALI emergency-lighting system
The unit also records operating information relating to the mains supply, battery, LED output and emergency operation. This BlackBox information can be read using compatible Tridonic software.
IMPORTANT OPERATING-MODE INFORMATION
Tridonic describes this emergency control gear as non-maintained.
However, it can be installed alongside a standard LED driver so that the same LED module operates:
- Normally from the separate LED driver while mains power is available
- At reduced emergency output from the EM converterLED following a mains failure
Therefore, a completed luminaire may provide maintained normal illumination, but the 89800661 emergency converter itself remains non-maintained emergency control gear.
IMPORTANT COMPATIBILITY INFORMATION
Before ordering, confirm:
- Tridonic article number 89800661
- Required 4.5 W emergency output
- LED forward-voltage range of 48–250 V
- One-, two- or three-hour emergency duration
- Compatibility with a five-cell, 6.0 V NiCd or NiMH battery
- Required battery capacity for the selected duration
- Compatibility with the normal LED driver
- Non-SELV insulation requirements
- Available installation space
- DALI system requirements
The associated normal LED driver must not exceed Tridonic’s specified current, inrush, voltage or load limits.
This model is not designed for LiFePO4 batteries. Use only a battery type listed as compatible in the current Tridonic datasheet.
Delivery Fees:
→ FREE Express Delivery (*1-2 working days) when you spend £40.00+VAT or more (*UK Mainland). Express Delivery for orders under £40.00+VAT is £4.99+VAT.
Scottish Highlands and Islands, Northern Ireland, the Isle of Man, the Isles of Scilly, and the Channel Islands require a delivery quote. Please contact us prior to ordering. We can now also quote International delivery.
Orders in stock placed before 4:00 PM Monday – Thursday (3:30 PM Friday) will be dispatched the same day and delivered within 1-2 working days (Monday – Friday *excluding weekends). All orders are tracked and insured, covering any unlikely loss or damage.
Orders are packaged and dispatched from our warehouse facility in Leeds, West Yorkshire, United Kingdom. We can also upgrade shipments to Pre-12:00 PM or Saturday Delivery on Friday Shipments, for example, but please call us on 0113 518 8886 and place the order over the phone instead.
Collection:
You may collect your goods from our trade counter located at Unit B8, Astra Business Park, Parkside Lane, Leeds LS11 5SZ, but please make sure to add a note at checkout saying you’re collecting your order. If your order is under £40.00+VAT, please call and place your order over the phone to remove the shipping charge. Someone in our customer support team will advise on your collection date and time. Please make sure you have a time confirmation before travelling.
Please note: Items on backorder will be sent out as soon as the stock is available. Orders placed after 3:30 PM on Friday and over the weekend will be dispatched on Monday. Orders placed on Bank holidays will be processed as normal, but dispatch will be the next working day.
Returns:
Enjoy up to 60 days to return any unused items.
Please see your returns paperwork (which may be affixed or inside your parcel) for instructions. You can find out more by visiting our delivery and returns page. We can also book a return for you. Please contact us on 0113 518 8886 to arrange.
Refunds are issued within 7 days of receiving the goods. Normally, within 3 days of receiving the goods.
Please see our Terms & Conditions page.
Technical Specifications
| Feature | Detail |
|---|---|
| Application | Emergency LED Lighting |
| Testing Method | Automatic self-test and DALI |
| Control and monitoring interface | DALI-2 |
| DALI standard | EN 62386-202 |
| Operating Mode | Non-Maintained |
| Rated emergency duration: | 1, 2 or 3 hours |
| Duration selection | Plug-in duration link |
| Typical emergency output power | 4.5 W |
| LED-module forward-voltage range: | 48–250 V |
| Permitted AC voltage range | 198–264 V |
| Rated supply voltage | 220–240 V AC |
| Output type | Constant Power |
| Battery compatibility | Approved NiCd or NiMH |
| Required number of battery cells | 5 |
| Nominal battery voltage | 6.0v |
| NiMH initial charging time | 20 Hours |
| LiFePO4 initial and fast recharge time | 24 Hours |
| Automatic function test | Weekly, 5 seconds |
| Automatic duration test | Annually, according to the selected 1-, 2- or 3-hour duration |
| Battery monitoring | Yes |
| Ambient temperature | −25°C to +55°C |
| Dimensions | 179 × 30 × 21 mm |
Reliable UK Stock | Dispatched from Leeds, West Yorkshire
KEY FEATURES
- Self-contained emergency LED conversion unit
- Non-maintained emergency control-gear operation
- 4.5 W constant emergency output
- Suitable for LED modules operating between 48 and 250 V
- Selectable one-, two- or three-hour emergency duration
- DALI interface for monitoring and control
- Automatic weekly function testing
- Automatic annual duration testing
- Compatible with approved five-cell Tridonic NiCd or NiMH batteries
- Intelligent battery-charging system
- Deep-discharge protection
- Battery reverse-polarity protection
- Three-pole LED changeover technology
- Bi-colour status-indicator support
- Rest-mode functionality
- BlackBox operating-data recording
- Emergency operation begins in under 0.5 seconds
- Up to 100,000-hour nominal operating life
- Five-year manufacturer guarantee, subject to Tridonic’s current conditions
Why not try
Tridonic ACCU-LiFePO4 1.5Ah 1A CON Emergency Lighting Battery – 28002317
MPN: 28002317
Tridonic ACCU-LiFePO4 3.0Ah 2A CON Emergency Lighting Battery – 28002318
MPN: 28002318
Tridonic ACCU-LiFePO4 3.0Ah 2B CON Side-by-Side Emergency Lighting Battery – 28002319
MPN: 28002319
Tridonic ACCU-LiFePO4 4.5Ah 3A CON Emergency Lighting Battery – 28002320
MPN: 28002320
Tridonic ACCU-LiFePO4 4.5Ah 3B CON Side-by-Side Emergency Lighting Battery – 28002321
MPN: 28002319
Tridonic ACCU-NiMH 2.2Ah 5B EM 5 Cell SS Emergency Battery - 28002093
MPN: 28002093
Tridonic EM converterLED BASIC 202 MH/LiFePO4 50V Emergency Driver – 89800575
MPN: 89800575
Tridonic EMconverterLED BASIC 202A MH/LiFePO4 250V Emergency LED Driver – 89800709
MPN: 89800709
Tridonic EMconverterLED BASIC 202A MH/LiFePO4 50V Emergency LED Driver – 89800708
MPN: 89800708
Tridonic EMconverterLED PRO 202 MH/LiFePO4 50V DALI-2 Emergency LED Driver – 89800627
MPN: 89800627
Tridonic EMconverterLED PRO 202A MH/LiFePO4 250V DALI-2 Emergency LED Driver – 89800903
MPN: 89800903